{"product_id":"hi-9814-groline-hydroponic-portable-ph-ec-tds-temperature-meter","title":"HI-9814 Groline Hydroponic Portable pH\/EC\/TDS\/Temperature Meter","description":"\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact, robust casing\u003c\/li\u003e\n\u003cli\u003eSimultaneous readout of pH, EC or TDS and °C\u003c\/li\u003e\n\u003cli\u003eSimple two button keyboard\u003c\/li\u003e\n\u003cli\u003eWaterproof design to withstand the humidity of a growing environment\u003c\/li\u003e\n\u003cli\u003eSpecialist multi-parameter electrode\u003c\/li\u003e\n\u003cli\u003eOptional green protective rubber holster - HI-710025\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HI-9814 boasts many advance features that are usually found in more expensive portable meters, including automatic calibration, buffer\/standard recognition and temperature compensation. On-screen tutorial message and indicators for the calibration status and stability can be viewed on the large multi-level LCD display.\u003c\/p\u003e\n\u003ch3\u003eSpecialist multi-parameter electrode designed for hydroponics\u003c\/h3\u003e\n\u003cp\u003eThe HI-1285-7 multi-parameter electrode is designed to overcome issues of measuring pH \u0026amp; EC\/TDS in hydroponic applications associated with aggressive chemicals, frequently faced by conventional multi-parameter electrodes.\u003c\/p\u003e\n\u003cp\u003eThe HI-9814 is supplied complete with the HI-1285-7 specialist electrode that features the following key benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePre-amplified pH electrode - prevents interference from humidity and sources of electrical noise including circulating pumps, motors and ballasts from grow lights.\u003c\/li\u003e\n\u003cli\u003eAmperometric EC\/TDS sensor - EC\/TDS readings are performed by a two-pin amperometric sensor, best suited to low conductivity applications\u003c\/li\u003e\n\u003cli\u003eBuilt-in temperature sensor - readings of pH and EC\/TDS must be temperature compensated in order to obtain accurate results. The built-in temperature sensor provides a speedy temperature reading which is then used to adjust the pH and EC\/TDS results accordingly for higher accuracy.\u003c\/li\u003e\n\u003cli\u003ePolypropylene body - the durable body of the HI-1285-7 electrode is chemically resistant to many aggressive chemicals used in hydroponics and protects all three sensors.\u003c\/li\u003e\n\u003cli\u003eDIN Connector - the HI-1285-7 has been specifically designed for use with the HI-9814 meter, the DIN connector means the probe is not interchangeable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003epH - Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 13.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic, one or two-points using standard buffers (standard pH 4.01, 7.01, 10.01); one point calibration using quick calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity - Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 6.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS - Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 3000 ppm (500 CF); 0 to 3999 ppm (700 CF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature - Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003epH: automatic; ED\/TDS: automatic with β set at 1.9%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic, one point at1.41 mS\/cm or 5.00 mS\/cm; one point calibration using quick calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 (500 ppm) or 0.7 (700 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-1285-7 polypropylene body, pre-amplified multi-parameter probe with internal temperature sensor, DIN connector and 1m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5V (3) AAA \/ approximately 500 hours of continuous use; auto-off after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eafter 8 minutes, 60 minutes, disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 to 50°C; RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e154 x 63 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e196g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Information:\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-9814 is supplied with HI-1285-7 multi-parameter probe, HI-50036 Quick Cal buffer solution sachet (3), HI-700661 pH electrode cleaning solution sachet for agriculture (3), 1.5 AAA batteries (3), and instructions and instrument quality certificate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":54497568588099,"sku":"HI-9814","price":345.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1864\/8365\/files\/1747.webp?v=1779439278","url":"https:\/\/korallifarmi.fi\/en\/products\/hi-9814-groline-hydroponic-portable-ph-ec-tds-temperature-meter","provider":"Korallifarmi","version":"1.0","type":"link"}