{"product_id":"hi-98162-portable-ph-meter-for-milk","title":"HI-98162 Portable pH meter for milk","description":"\u003cp\u003eHI-98162 is a rugged, waterproof, Foodcare portable meter that measures pH and temperature using the FC1013 probe for milk products. This professional, waterproof meter complies with IP67 standards.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWaterproof - The professional meter is IP67 rated.\u003c\/li\u003e\n\u003cli\u003eCAL CheckTM - Alerts users to problems.\u003c\/li\u003e\n\u003cli\u003eAutomatic or manual temperature compensation.\u003c\/li\u003e\n\u003cli\u003eCalibration.\u003c\/li\u003e\n\u003cli\u003e200 hour battery life approximately with 1.5V AA batteries (x4) .\u003c\/li\u003e\n\u003cli\u003eClear display.\u003c\/li\u003e\n\u003cli\u003eAuto hold.\u003c\/li\u003e\n\u003cli\u003eCalibration timeout.\u003c\/li\u003e\n\u003cli\u003eConnectivity.\u003c\/li\u003e\n\u003cli\u003eGLP.\u003c\/li\u003e\n\u003cli\u003eIntuitive keypad.\u003c\/li\u003e\n\u003cli\u003eCarry case and accessories.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCAL Check™ feature\u003c\/h3\u003e\n\u003cp\u003eThe HI-98162 has the Hanna unique CAL Check™ feature that alerts the user to potential problems during the calibration process. This is a very important for the food processor since it is likely that the probe will be coated with the solids found in the food product being measured. This coating can easily lead to errors in pH measurement. By comparing previous calibration data to the current calibration, the meter will inform the user, with display prompts, when the probe needs to be cleaned, replaced, or if the pH buffer might be contaminated. After calibration, the overall probe condition is displayed on screen as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode, both of which can be found in the GLP data.\u003c\/p\u003e\n\u003ch3\u003eAutoHold\u003c\/h3\u003e\n\u003cp\u003ePressing the AutoHold virtual key in measurement mode, the meter will freeze and automatically log a stable reading. An “out of calibration range” warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.\u003c\/p\u003e\n\u003ch3\u003eHelp menu\u003c\/h3\u003e\n\u003cp\u003eA contextual help menu based on the screen that is currently being viewed can be accessed at any time by the press of a dedicated button.\u003c\/p\u003e\n\u003ch3\u003eLog-on demand\u003c\/h3\u003e\n\u003cp\u003eThe log-on-demand mode allows the user to record and save up to 200 samples. The logged data, along with the associated GLP data, can then be recalled or transferred to a PC with Hanna’s HI-920015 micro USB cable and HI-92000 software for traceability in record keeping for specific product batches. GLP data includes date, time, calibration buffers, offset, and slope, and is directly accessible by pressing the dedicated GLP key.\u003c\/p\u003e\n\u003ch3\u003eLCD screen\u003c\/h3\u003e\n\u003cp\u003eThe high contrast, graphic LCD screen is easy to view outdoors in bright sunlight as well as in low-lit areas with the backlight. A combination of dedicated and virtual keys allows for easy, intuitive meter operation in a choice of languages.\u003c\/p\u003e\n\u003ch3\u003eCarry case\u003c\/h3\u003e\n\u003cp\u003eThe compact, durable HI-720161 carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter and electrode, beakers, buffer solutions and cleaning solutions.\u003c\/p\u003e\n\u003ch3\u003eAbout the FC1013 electrode\u003c\/h3\u003e\n\u003cp\u003eThe HI-98162 uses the FC1013 amplified pH electrode with PVDF body. This specialised electrode offers numerous features that improve pH testing for milk producers. An integrated temperature sensor allows for temperature compensated pH measurements without the need for a separate temperature probe. The contact between the bulb’s large surface area and the milk sample ensures a stable calibration and measurement.\u003c\/p\u003e\n\u003cp\u003eAn integral part of any pH electrode is the reference junction. The reference junction is a part of the electrode that allows for the flow of ions located in the reference cell into the sample being tested. It is vital that this flow occurs in order to complete an electrical circuit, which ultimately determines the pH value. Any clogging of the junction will prevent completion of the circuit, resulting in readings that are erratic or constantly drifting.\u003c\/p\u003e\n\u003cp\u003eThe FC1013 probe utilizes a secondary reference chamber with ceramic outer junction allowing aqueous silver free electrolyte to flow slowly through the porous ceramic frit providing accurate readings for aqueous samples.\u003c\/p\u003e\n\u003cp\u003eThe durable PVDF body of the FC1013 ensures pH measurements can be safely taken on the dairy farm or production floor. The components of the electrode are also able to withstand a wider range of temperatures to allow for accuracy during stages such as pasteurization, which requires heating to temperatures near 72°C (161°F).\u003c\/p\u003e\n\u003ch3\u003eFC1013 Foodcare pH and temperature electrode for milk products:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePVDF plastic body\u003c\/li\u003e\n\u003cli\u003eSpherical glass tip\u003c\/li\u003e\n\u003cli\u003eRefillable with silver free electrolyte\u003c\/li\u003e\n\u003cli\u003eOpen junction design prevents clogging\u003c\/li\u003e\n\u003cli\u003eGeneral purpose pH sensing glass for a wide range of temperatures\u003c\/li\u003e\n\u003cli\u003eBuilt-in temperature sensor for compensated measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIP67 – Dust-tight and protected against the effects of temporary immersion in water up to 1m.\u003c\/p\u003e\n\u003cp\u003eRecommended cleaning solution: HI-700640p Cleaning solution for milk deposits, 25 x 20ml sachets.\u003c\/p\u003e\n\u003cp\u003ePC Connectivity – Opto-isolated USB with optional HI-92000 software and micro USB cable.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003epH range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1; ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eup to five point calibration, seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + five custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±2000mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.4˚C (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003emanual or automatic from -20.0 to 120.0˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003efrom 80 to 110%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode\/Probe\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFC1013 pre-amplified pH probe with internal temperature sensor, quick connect DIN connector and 1m (3.3ft cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOhms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog-on demand\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e200 samples (100pH and 100mV range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Connectivity\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eopto-isolated USB with optional HI-92000 software and micro USB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4) \/ approximately 200 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003euser selectable: 5, 10, 30, 60 min or can be disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50˚C; RH 100% (IP67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e400g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering information\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-98162 is supplied with FC1013 PVDF body pH electrode, HI-7004M pH 4.01 buffer solution (230mL), HI-7007M pH 7.01 buffer solution (230ml), HI-700640 electrode cleaning solution for milk deposits sachets (2), 100ml plastic beaker (2), 1.5V AA Batteries (4), HI-92000 PC software, HI-920015 micro USB cable, instruction manual with quick start guide, instrument quality certificate and HI-720161 hard carrying case.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2 years (probe 6 months)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":54497563017539,"sku":"HI-98162","price":988.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1864\/8365\/files\/1792.webp?v=1779438857","url":"https:\/\/korallifarmi.fi\/en\/products\/hi-98162-portable-ph-meter-for-milk","provider":"Korallifarmi","version":"1.0","type":"link"}