{"product_id":"hi-98194-multiparameter-ph-orp-ec-do-waterproof-meter","title":"HI-98194 Multiparameter pH\/ORP\/EC\/DO Waterproof Meter","description":"\u003cp\u003e\u003cspan\u003eHI-98194 provides multiparameter measurement in a compact and rugged IP67 waterproof \u003c\/span\u003eenclosure. Ideal for demanding application, this meter features our rugged, quick connect multi-function probe with field replaceable sensors. The HI-98194 measures pH\/mV, ORP, Conductivity, TDS, Resistivity, Salinity, Seawater, Dissolved Oxygen, Atmospheric Pressure and Temperature.\u003c\/p\u003e\n\u003cp\u003eAlso available in 10m, 20m and 40m cables. See table below for details. Prices will vary.\u003c\/p\u003e\n\u003cp\u003eA backlit, graphic LCD provides easy to read resolution even in low-lit areas. A combination of dedicated and soft keys allows easy, intuitive operation in a choice of languages.\u003c\/p\u003e\n\u003cp\u003eHI-98194 allows users to store up to 45,000 continuous or log-on demand samples with logging intervals from one second to three hours. Logged data can be later transferred to a PC with the HI-920015 micro USB cable and Hanna software.\u003c\/p\u003e\n\u003cp\u003eComprehensive GLP data includes data from the last five calibrations. The contextual Help Menu can be accessed to obtain on-screen information and assistance about each feature at the touch of a button.\u003c\/p\u003e\n\u003cp\u003eThe HI-7698194 probe features a quick connect DIN connector to make attaching and removing the probe simple and easy.\u003c\/p\u003e\n\u003cp\u003eHI-98194 provides multi-parameter measurement in a compact and rugged IP67 waterproof enclosure. Ideal for demanding application, this meter features our rugged, quick connect multi-function probe with field replaceable sensors.\u003c\/p\u003e\n\u003cp\u003eA backlit, graphic LCD provides easy to read resolution even in low-lit areas. A combination of dedicated and soft keys allows easy, intuitive operation in a choice of languages.\u003c\/p\u003e\n\u003cp\u003eHI-98194 allows users to store up to 45,000 continuous or log-on demand samples with logging intervals from one second to three hours. Logged data can be later transferred to a PC with the HI-920015 micro USB cable and Hanna software.\u003c\/p\u003e\n\u003cp\u003eComprehensive GLP data includes data from the last five calibrations. The contextual Help Menu can be accessed to obtain on-screen information and assistance about each feature at the touch of a button.\u003c\/p\u003e\n\u003cp\u003eThe HI-7698194 probe features a quick connect DIN connector to make attaching and removing the probe simple and easy.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eKey features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIP67 rated waterproof, rugged enclosure for meter, IP68 for probe\u003c\/li\u003e\n\u003cli\u003eColour coded, field replaceable sensors\u003c\/li\u003e\n\u003cli\u003eAuto sensor recognition\u003c\/li\u003e\n\u003cli\u003eAutomatic logging of up to 45,000 samples\u003c\/li\u003e\n\u003cli\u003eStore measurement data at the press of a button\u003c\/li\u003e\n\u003cli\u003eOn-screen context specific help is readily available at the press of a button\u003c\/li\u003e\n\u003cli\u003ePC connectivity via opto-isolated micro-USB with Hanna software\u003c\/li\u003e\n\u003cli\u003eUp to 360 hours of battery life, powered by (4) 1.5Vbatteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003epH specific features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eUp to three point calibration with five standard buffers and one custom buffer available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eEC\/TDS\/Resistivity specific features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eSingle point calibration from six standards (84?S\/cm, 1413 ?S\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80 mS\/cm, 111.8 mS\/cm)\u003c\/li\u003e\n\u003cli\u003eAutomatic temperature compensation configurable temperature coefficient range from 0.00 to 6.00%\/°C\u003c\/li\u003e\n\u003cli\u003eChoice of reference temperatures at 20 or 25°C\u003c\/li\u003e\n\u003cli\u003eAbsolute conductivity can be displayed along with the temperature compensated value\u003c\/li\u003e\n\u003cli\u003eAuto ranging\u003c\/li\u003e\n\u003cli\u003ePractical Salinity Scale (PSU)based on conductivity calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eDissolved Oxygen specific features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eDisplay units in % saturation of mg\/L (ppm)\u003c\/li\u003e\n\u003cli\u003eSalinity compensation for concentration\u003c\/li\u003e\n\u003cli\u003ePressure compensation for concentration\u003c\/li\u003e\n\u003cli\u003eBuilt-in barometer with user-selectable units (mmHg, inHg, atm, psi, kPa, mbar)\u003c\/li\u003e\n\u003cli\u003eTemperature compensation\u003c\/li\u003e\n\u003cli\u003eAutomatic polarisation of probe at startup\u003c\/li\u003e\n\u003cli\u003eReady to use HDPE pre-tensioned membrane caps are easy to replace\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eColour Coded, Field Replaceable Sensors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eHI-7698194-0 Double Ceramic Junction pH Sensor\u003c\/li\u003e\n\u003cli\u003eHI-7698194-1 pH \u0026amp; platinum ORP Sensor\u003c\/li\u003e\n\u003cli\u003eHI-7698194-3 Four ring, stainless steel conductivity sensor\u003c\/li\u003e\n\u003cli\u003eHI-7698194-2 Galvanic dissolved oxygen sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOn screen features\u003c\/h3\u003e\n\u003ch3\u003eSetup screen\u003c\/h3\u003e\n\u003cp\u003eOur extensive setup screen features a host of configurable options such as time, date, temperature units and different languages for help screens and guides.\u003c\/p\u003e\n\u003ch3\u003eQuick Calibration\u003c\/h3\u003e\n\u003cp\u003eThe quick calibration feature allows for a single point calibration for pH, conductivity, and dissolved oxygen all in a few simple steps.\u003c\/p\u003e\n\u003ch3\u003eProbe Details\u003c\/h3\u003e\n\u003cp\u003eThe HI-7698194 is a multiparameter pH\/EC\/DO\/Temperature probe for use with the HI-98194 portable meter.\u003c\/p\u003e\n\u003cp\u003eIt features a quick connect that makes a waterproof connection with the meter. Sensors are automatically recognised by the probe and meter when connected.\u003c\/p\u003e\n\u003cp\u003eAny ports not used on the probe will not have the parameter displayed on the meter. Sensor replacement is quick and easy with field replaceable, screw type connectors that are colour coded for easy sensor identification.\u003c\/p\u003e\n\u003cp\u003eThe probe features a multistrand-multiconductor shielded cable with 4m, 10m, 20m, and 40m lengths available. It’s rugged, waterproof design makes it ideal for field use. IP68 sensor.\u003c\/p\u003e\n\u003ch3\u003eRugged Carrying Case\u003c\/h3\u003e\n\u003cp\u003eThe HI-98194 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDin Connection\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eIP68:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eElectrode is dust-tight and protected against the effects of continuous immersion in water beyond 1m.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003epH\/mV Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\/± 600.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH\/ ±0.5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic one, two or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic at one custom point (relative mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 200 mS\/cm (absolute EC up to 400 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eManual: 1μS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm;\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eautomatic\u003c\/b\u003e: 1μS\/cm from 0 to 9999 μS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm;\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eautomatic mS\/cm\u003c\/b\u003e: 0.001 mS\/cm from 0.000 to 9.999 mS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or ± 1μS\/cm whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic single point, with six standard solutions (84μS\/cm, 1413μS\/cm, 5.00mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm) or custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 400.0 ppt (g\/L) (the maximum value depends on the TDS factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003emanual\u003c\/b\u003e: 1 ppm (mg\/L); 0.001 ppt (g\/L); 0.1 ppt (g\/L); 1 ppt (g\/L);\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eautomatic\u003c\/b\u003e: 1ppm (mg\/L) from 0 to 9999 ppm (mg\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 400.0 ppt (g\/L);\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eautomatic ppt (g\/L):\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.001 ppt (g\/L) from 0.000 to 9.999 PPT(g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 400.0 pp (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or ±1 ppm (mg\/L) whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 999999 Ω.cm; 0 to 1000.0 kΩ.cm; 0 to 1.0000 MΩ.cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003edependent on resistivity reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 70.00 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% of reading or ±0.01 PSU whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater σ Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 σt, σ\u003csub\u003e0\u003c\/sub\u003e, σ\u003csub\u003e15\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater σ Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 σ t, σ\u003csub\u003e0\u003c\/sub\u003e, σ\u003cspan\u003e \u003c\/span\u003e\u003csub\u003e15\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater σ Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 σ t, σ\u003csub\u003e0\u003c\/sub\u003e, σ\u003cspan\u003e \u003c\/span\u003e\u003csub\u003e15\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater σ Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 500.0%, 0.00 to 50.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.%; 0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 300.0%; ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%; ±3% of reading; 0.00 to 30.00 ppm (mg\/L); ±1.5% of reading or ±0.10 ppm (mg\/L). whichever is greater; 30.00 ppm (mg\/L) to 50.00 ppm (mg\/L); ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic one or two points at 0.100% or one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Pressure Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Pressure Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Pressure Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±3mm Hg within ±15°C from the temperature during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Pressure Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-5.00 to 55.00°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.15°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Specifications\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Maximum probe immersion\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDepth - 20 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Temperature compensation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic from -5 to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Logging Memory\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e45,000 records (continuous logging or log-on demand of all parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Logging Interval\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eone second to three hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e PC Connectivity\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003evia USB (with Hanna PC software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Environment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C; RH 100% IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Battery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4)\/approximately 360 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Dimensions\/Weight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2 mm\/400g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering information:\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-98194 is supplied with HI-7698194 probe, HI-7698194-1 pH\/ORP sensor, HI-7698194-3 EC sensor, HI-7698194-2 DO sensor, HI-76981942 Probe maintenance kit (HI-7042S DO electrolyte solution, DO membrane caps (5), O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI-9298194 Hanna PC software, HI-920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermo-formed insert.\u003cbr\u003eHI-98194 is supplied with HI-7698194\/4 multiparameter probe with 4m cable Also available:\u003cbr\u003eHI-98194\/10 is supplied with HI-7698194\/10 multiparameter probe with 10m cable\u003cbr\u003eHI-98194\/20 is supplied with HI-7698194\/20 multiparameter probe with 20m cable\u003cbr\u003eHI-98194\/40 is supplied with HI-7698194\/40 multiparameter probe with 40m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-710034 Orange protective rubber boot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":54497606271299,"sku":"HI-98194","price":2784.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1864\/8365\/files\/1712.webp?v=1779441504","url":"https:\/\/korallifarmi.fi\/en\/products\/hi-98194-multiparameter-ph-orp-ec-do-waterproof-meter","provider":"Korallifarmi","version":"1.0","type":"link"}