{"product_id":"hi-98196-multiparameter-ph-orp-do-waterproof-meter","title":"HI-98196 Multiparameter pH \/ORP\/ DO Waterproof Meter","description":"\u003cp\u003eHI-98196 provides multi-parameter measurement in a compact and rugged IP67 waterproof enclosure. Ideal for demanding application, this meter features our rugged, quick connect multi-function probe with field replaceable sensors. The HI-98196 measures pH\/mV, ORP, Dissolved Oxygen, Atmospheric Pressure and Temperature\u003c\/p\u003e\n\u003cp\u003eA backlit, graphic LCD provides easy to read resolution even in low-lit areas. A combination of dedicated and soft keys allows easy, intuitive operation in a choice of languages.\u003c\/p\u003e\n\u003cp\u003eHI-98196 allows users to store up to 45,000 continuous or log-on demand samples with logging intervals from one second to three hours. Logged data can be later transferred to a PC with the HI-920015 micro USB cable and Hanna software.\u003c\/p\u003e\n\u003cp\u003eComprehensive GLP data includes data from the last five calibrations. The contextual Help Menu can be accessed to obtain on-screen information and assistance about each feature at the touch of a button.\u003c\/p\u003e\n\u003ch3\u003epH specific features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUp to three point calibration with five standard buffers and one custom buffer available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDissolved Oxygen specific features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisplay units in % saturation of mg\/L (ppm)\u003c\/li\u003e\n\u003cli\u003eSalinity compensation for concentration\u003c\/li\u003e\n\u003cli\u003ePressure compensation for concentration\u003c\/li\u003e\n\u003cli\u003eBuilt-in barometer with user-selectable units (mmHg, inHg, atm, psi, kPa, mbar)\u003c\/li\u003e\n\u003cli\u003eTemperature compensation\u003c\/li\u003e\n\u003cli\u003eAutomatic polarisation of probe at startup\u003c\/li\u003e\n\u003cli\u003eReady to use HDPE pre-tensioned membrane caps are easy to replace\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HI-7698196 probe features a quick connect DIN connector to make attaching and removing the probe simple and easy.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIP67 rated waterproof, rugged enclosure for meter, IP68 for probe\u003c\/li\u003e\n\u003cli\u003eColour-coded, field replaceable sensors\u003c\/li\u003e\n\u003cli\u003eAuto sensor recognition\u003c\/li\u003e\n\u003cli\u003eAutomatic logging of up to 45,000 samples\u003c\/li\u003e\n\u003cli\u003eStore measurement data at the press of a button\u003c\/li\u003e\n\u003cli\u003eOn-screen context specific help is readily available at the press of a button\u003c\/li\u003e\n\u003cli\u003ePC connectivity via opto-isolated micro-USB with Hanna software\u003c\/li\u003e\n\u003cli\u003eUp to 360 hours of battery life, powered by (4) 1.5V batteries\u003c\/li\u003e\n\u003cli\u003eThe HI-7698196 probe features a quick connect DIN connector for a water tight connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIP68 - Electrode is dust-tight and protected against the effects of continuous immersion in water beyond 1m.\u003c\/p\u003e\n\u003cp\u003ePC Interface - Download test results to a computer programmed with HANNA’s Windows® compatible software (HI-92000), directly from equipment via a USB port or a RS232 cable outlet.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003epH\/mV Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\/± 600.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH\/ ±0.5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic up to three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic at one custom point (relative mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 500.0%, 0.00 to 50.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.%; 0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 300.0%; ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%; ±3% of reading; 0.00 to 30.00 ppm (mg\/L); ±1.5% of reading or ±0.10 ppm (mg\/L). whichever is greater; 30.00 ppm (mg\/L) to 50.00 ppm (mg\/L); ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic one or two points at 0.100% or one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Pressure Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Pressure Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Pressure Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±3mm Hg within ±15°C from the temperature during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Pressure Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-5.00 to 55.00°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.15°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Specifications\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Maximum probe immersion\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDepth - 20 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Temperature compensation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic from -5 to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Logging Memory\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e45,000 records (continuous logging or log-on demand of all parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Logging Interval\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eone second to three hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e PC Connectivity\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003evia USB (with Hanna PC software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Environment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C; RH 100% IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Battery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4)\/approximately 360 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Dimensions\/Weight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2 mm\/400g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering information:\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-98196 is supplied with HI-7698196\/4 multiparameter probe, HI-7698194-1 pH\/ORP sensor, HI-7698194-2 DO sensor, HI-9828-20 quick calibration solution, HI-76981942 Probe maintenance kit, HI-76981943 Calibration beaker, HI-9298194 Hanna PC software, HI-920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom insert.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":54497604501827,"sku":"HI-98196","price":1684.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1864\/8365\/files\/1713.webp?v=1779441311","url":"https:\/\/korallifarmi.fi\/en\/products\/hi-98196-multiparameter-ph-orp-do-waterproof-meter","provider":"Korallifarmi","version":"1.0","type":"link"}