{"product_id":"hi-98594-multiparameter-meter-with-bluetooth-connectivity","title":"HI-98594 Multiparameter Meter with Bluetooth Connectivity","description":"\u003ch1\u003eHI-98594 Multiparameter Portable Meter with Bluetooth Connectivity\u003c\/h1\u003e\n\u003cp\u003eThe HI-98594 Portable Multiparameter Meter is designed to withstand the harsh environmental conditions required for testing in the field, with rugged construction and a practical multi-sensor probe for ease of use across a range of applications. This handheld multimeter measures 14 individual water parameters and meets the IP67 standard, with the probe meeting the IP68 standard for continuous immersion within water. \u003c\/p\u003e\n\u003cp\u003eThe HI-98594 features Bluetooth 5.0 with full connectivity to the Hanna Lab app, allowing for easy, reliable cloud-based transfer of data in the field.\u003c\/p\u003e\n\u003cp\u003eThis water testing meter is an ideal solution for measurement in a range of sectors, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSurface water measurement\u003c\/li\u003e\n\u003cli\u003eSeawater measurement\u003c\/li\u003e\n\u003cli\u003eWastewater measurement\u003c\/li\u003e\n\u003cli\u003eEducation and research applications\u003c\/li\u003e\n\u003cli\u003eGroundwater measurement\u003c\/li\u003e\n\u003cli\u003eAquaculture monitoring\u003c\/li\u003e\n\u003cli\u003eConstruction and environmental remediation testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eHI-98594 Advanced Multiparameter Meter Features\u003c\/h2\u003e\n\u003ch3\u003ePrecision in your palm\u003c\/h3\u003e\n\u003cp\u003eThe HI-98594 is an advanced, highly accurate handheld meter, providing a rugged and practical solution for measuring water anywhere. The handheld design of this meter allows it to be utilised in a wide range of environments, with a portable carrying case to enable convenient movement to different sites.\u003c\/p\u003e\n\u003ch3\u003eReliable water testing anywhere\u003c\/h3\u003e\n\u003cp\u003eThis handheld advanced water analysis meter is designed to withstand a wide range of environments and applications, from groundwater analysis to aquaculture monitoring. The multi-sensor probe includes all the necessary sensors for simultaneous measurement, ensuring accuracy in testing results across multiple parameters.\u003c\/p\u003e\n\u003ch3\u003eMeasure 14 parameters\u003c\/h3\u003e\n\u003cp\u003eThe HI-98594 is equipped with a multi-sensor probe for the measurement of 14 key water parameters, with the ability to display from 1 to 12 parameters at once on the screen. These parameters include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003epH\u003c\/li\u003e\n\u003cli\u003emV\u003c\/li\u003e\n\u003cli\u003eORP\u003c\/li\u003e\n\u003cli\u003eDissolved Oxygen (ppm)\u003c\/li\u003e\n\u003cli\u003eDissolved Oxygen (%)\u003c\/li\u003e\n\u003cli\u003eEC\u003c\/li\u003e\n\u003cli\u003eEC (absolute)\u003c\/li\u003e\n\u003cli\u003eResistivity\u003c\/li\u003e\n\u003cli\u003eTDS\u003c\/li\u003e\n\u003cli\u003eSalinity\u003c\/li\u003e\n\u003cli\u003eSeawater σ\u003c\/li\u003e\n\u003cli\u003eTurbidity\u003c\/li\u003e\n\u003cli\u003eAtmospheric Pressure\u003c\/li\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMulti-sensor probe for ease of use\u003c\/h3\u003e\n\u003cp\u003eThe HI-7698594 probe provides an easy-to-use solution for testing multiple parameters at once. This pre-installed probe includes a combined pH\/ORP sensor, a combined EC\/Turbidity sensor, an Optical Dissolved Oxygen sensor and a temperature sensor as standard. Simple, screw-type, colour-coded connectors and automatic sensor identification make swapping and changing sensors simple.\u003c\/p\u003e\n\u003ch3\u003eHigh precision everywhere you go\u003c\/h3\u003e\n\u003cp\u003eThe compact, handheld size of the HI-98594 makes it easily portable and convenient in even the most challenging environments. The addition of a rugged carrying case with a thermoformed, moulded interior ensures all accessories and solutions can be securely stored and easily moved.\u003c\/p\u003e\n\u003ch3\u003eData logging capability\u003c\/h3\u003e\n\u003cp\u003eThe HI-98594 water parameter meter has the capacity to store up to 50,000 samples at intervals between 1 second and 3 hours. Long-on-demand is available to store measurement data, and all logged information is transferred in a universal .csv format on connection to a computer. No additional software is required to extract data.\u003c\/p\u003e\n\u003ch3\u003eSmart solutions for smarter testing\u003c\/h3\u003e\n\u003cp\u003eBluetooth 5.0 connectivity enables the HI-98594 to send data directly to the Hanna Lab application, for completely remote access and transfer via smartphone or tablet. Log-on-demand and automatic logging are available for all parameters, and data can easily be reviewed and shared as an email, removing the time delay typically required to pass data on from fieldwork.  \u003c\/p\u003e\n\u003cp\u003eAutomatic firmware updates for the meter and probe are available directly through the Hanna Lab app, requiring no computer connection to ensure the meter is up-to-date.\u003c\/p\u003e\n\u003ch3\u003eQuick-DIN for waterproof connection\u003c\/h3\u003e\n\u003cp\u003eThis multiparameter handheld meter connects to the included probe through a single waterproof Quick-DIN connector, making attaching and removing the probe a quick and easy task. The meter automatically detects the probe when connected, with no additional steps required.\u003c\/p\u003e\n\u003ch3\u003eEasy transfer and charging\u003c\/h3\u003e\n\u003cp\u003eA standard USB Type-C port allows for the easy transfer of data to a memory stick, PC, or other compatible devices. This port is also used to charge the internal lithium-ion battery.\u003c\/p\u003e\n\u003ch3\u003eDual-power supply for continual testing\u003c\/h3\u003e\n\u003cp\u003eThe HI-98594 features a built-in lithium-ion battery that provides the primary charge for the instrument. A secondary power source, 1.5 AA alkaline batteries, ensures continued operation of the portable water meter when the lithium-ion battery runs out, with automatic switching for seamless measurement.\u003c\/p\u003e\n\u003ch2\u003eAbout the HI-7698594\u003c\/h2\u003e\n\u003cp\u003eThis compact multi-sensor probe is fully waterproof and equipped with a protective shield, making it ideal for water measurements in difficult environments. The HI-7698594 includes the following colour-coded, automatically-recognised sensors as standard:\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHI-7698194-1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eCombined pH\/ORP sensor\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePEI-body pH sensor with a glass tip\u003c\/li\u003e\n\u003cli\u003ePlatinum Sensor for ORP\u003c\/li\u003e\n\u003cli\u003eDouble junction reference with gel KCl electrolyte\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eHI-7698594-4\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eCombined EC\/Turbidity sensor\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFour-electrode conductivity sensor\u003c\/li\u003e\n\u003cli\u003eTurbidity Sensor meets ISO 7027 standards\u003c\/li\u003e\n\u003cli\u003eTurbidity range from 0.0 to 1000 FNU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eHI-7698194-1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eOptical Dissolved Oxygen sensor\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNo need for frequent calibrations\u003c\/li\u003e\n\u003cli\u003eQuick readings and great stability\u003c\/li\u003e\n\u003cli\u003eHigh precision at very low oxygen values\u003c\/li\u003e\n\u003cli\u003eIdeal for difficult applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAn optional Flow Cell (HI-7698297) is also available in combination with the HI-98594 and HI-7698594 to suit specific application requirements such as low-flow sampling in groundwater analysis.\u003c\/p\u003e\n\u003ch3\u003ePart of the HI-98XXX family\u003c\/h3\u003e\n\u003cp\u003eThe HI-98594 water analysis meter is part of the HI-98XXX family of handheld meters for water testing. These meters cover a wide range of different parameters and include different options suitable for various applications, industry requirements and standards. \u003ca href=\"https:\/\/www.hannainstruments.co.uk\/709-multi-parameter-devices\"\u003eShop the full range here\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI-98594\/Screenshot_5.png\" alt=\"\" width=\"1138\" height=\"565\"\u003e\u003c\/p\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003ch3\u003eWhat industries is the HI-98594 suitable for?\u003c\/h3\u003e\n\u003cp\u003eThe HI-98594 is a versatile water meter that is suitable for the measurement of pH, ORP, DO, EC and Turbidity in a wide range of environments. Some of the most popular fields for this meter include analysis of seawater, groundwater and wastewater. In addition, the accuracy and practical design of this meter make it highly suitable for education and research, aquaculture and the environmental remediation and construction sectors. .\u003c\/p\u003e\n\u003ch3\u003eHow big is the HI-98594?\u003c\/h3\u003e\n\u003cp\u003eThe HI-98594 is a compact instrument designed for field testing. This handheld multimeter weighs 435g and has dimensions of 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”). The rugged carrying case that is included with this meter allows the HI-98594 and all accessories and solutions to be easily and securely carried on-site.\u003c\/p\u003e\n\u003ch3\u003eWhat is included with the HI-98594?\u003c\/h3\u003e\n\u003cp\u003eThe HI-98594 is supplied with the HI-7698594 and all listed sensors, a protective probe shield, a probe maintenance kit, a long calibration beaker, quick calibration standard solutions, a zero oxygen solution set, a 0 FNU calibration solution, a 20 FNU calibration solution, a 200 FNU calibration solution, a protective rubber boot and a rugged carrying case. Quality certificates and a quick reference guide are also included, alongside a USB cable and 4x 1.5V AA alkaline batteries.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003epH \/ mV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH \/ ±600.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 pH \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH \/ ±0.5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic one-point Quick Calibration using HI-9828-25; automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eORP\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic at one custom point (relative mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 200 mS\/cm\u003cbr\u003e0 to 400 mS\/cm (absolute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003emanual: 1 μS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm; 1 mS\/cm;\u003cbr\u003eautomatic: 1 μS\/cm from 0 to 9999 μS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm;\u003cbr\u003eautomatic (mS\/cm): 0.001 mS\/cm from 0.000 to 9.999 mS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or ±1 μS\/cm whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOne-point Quick Calibration using HI-9828-25;\u003cbr\u003eOne point, with six standard solutions (84 μS\/cm, 1413 μS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm) or custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTDS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 400000 (mg\/L) (the maximum value depends on the TDS factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003emanual: 1 ppm (mg\/L); 0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L); 1 ppt (g\/L);\u003cbr\u003eautomatic: 1 ppm (mg\/L) from 0 to 9999 ppm (mg\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 400.0 ppt (g\/L);\u003cbr\u003eautomatic ppt (g\/L): 0.001 ppt (g\/L) from 0.000 to 9.999 ppt (g\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or ±1 ppm (mg\/L) whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResistivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Ω•cm; 0.1 k Ω•cm; 0.0001 M Ω•cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSalinity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 70.00 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% of reading or ±0.01 PSU whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOne point, using a custom solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeawater σ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTurbidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 99.9 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 FNU from 0.0 to 99.0 FNU\u003cbr\u003e1 FNU from 100 to 1000 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3 FNU or ±2% of reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic 1, 2, 3 points at 0, 20 and 200 FNU or custom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDissolved Oxygen\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 500.0% saturation; 0.00 to 50.00 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1% saturation; 0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1.5% of reading ±0.01mg\/L for 0.00-20.00mg\/L;\u003cbr\u003e±5% of reading for 20.00-50.00mg\/L;\u003cbr\u003e±1.5% of reading ±0.1% for 0.0-200.0%;\u003cbr\u003e±5% of reading for 200.0-500.0% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOne point, quick calibration in water saturated air; One or two-point at 100% and 0%; One point using a custom solution, % saturation or mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude Compensation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic: 420 to 850mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAtmospheric Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±3 mm Hg within ±15°C from calibration temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-5.00 to 55.00°C; 23.00 to 122.00°F; 268.15 to 323.15K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01°C; 0.01°F; 0.01K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.15°C; ±0.27°F; ±0.15K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOne point using a custom value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdditional Specifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic from -5 to 50°C (23 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Logging Memory\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e50,000 records interval logging or 15,000 records, log-on-demand of all parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Logging Interval\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eone second to three hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Connectivity\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-C (HOST) functions – Mass storage host; USB-C (device) functions – Mass storage device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Environment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH 100% IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Battery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4); built-in Li-ion battery (1) \/ 90 hours (AA, without backlighting and Bluetooth) 35 hours (Li-ion battery, without backlighting and Bluetooth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Dimensions \/ Weight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) \/ 435g (13.3 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"width: 100.036%; height: 447.2px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.4911%; height: 19.6px;\"\u003e\u003cspan\u003eProbe Specification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 0%; height: 19.6px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1221%; height: 19.6px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.4911%; height: 19.6px;\"\u003eSensor Inputs\u003c\/td\u003e\n\u003ctd style=\"width: 0%; height: 19.6px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1221%; height: 19.6px;\"\u003eThree - pH\/ORP, DO, EC or EC\/Turbidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 22.4911%; height: 39.2px;\"\u003eSample Environment\u003c\/td\u003e\n\u003ctd style=\"width: 0%; height: 39.2px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1221%; height: 39.2px;\"\u003eFresh, brackish, seawater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 22.4911%; height: 39.2px;\"\u003eWaterproof Protection\u003c\/td\u003e\n\u003ctd style=\"width: 0%; height: 39.2px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1221%; height: 39.2px;\"\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 22.4911%; height: 39.2px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 0%; height: 39.2px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1221%; height: 39.2px;\"\u003e-5 to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 22.4911%; height: 39.2px;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 0%; height: 39.2px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1221%; height: 39.2px;\"\u003e-20 to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.4911%; height: 19.6px;\"\u003eMaximum depth\u003c\/td\u003e\n\u003ctd style=\"width: 0%; height: 19.6px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1221%; height: 19.6px;\"\u003e20m (66 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 22.4911%; height: 39.2px;\"\u003eDimensions (without cable)\u003c\/td\u003e\n\u003ctd style=\"width: 0%; height: 39.2px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1221%; height: 39.2px;\"\u003e342 mm; 46mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 22.4911%; height: 39.2px;\"\u003eWeight (without sensors)\u003c\/td\u003e\n\u003ctd style=\"width: 0%; height: 39.2px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1221%; height: 39.2px;\"\u003e570g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 22.4911%; height: 39.2px;\"\u003eCable specification\u003c\/td\u003e\n\u003ctd style=\"width: 0%; height: 39.2px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1221%; height: 39.2px;\"\u003eMultistrand-multiconductor shielded cable with internal strength member rated for 68kg (150lb) intermittent use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 114px;\"\u003e\n\u003ctd style=\"width: 22.4911%; height: 114px;\"\u003eWetted materials\u003c\/td\u003e\n\u003ctd style=\"width: 0%; height: 114px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1221%; height: 114px;\"\u003e\n\u003cp\u003eBody – ABS\u003cbr\u003eThreads – Nylon\u003cbr\u003eShield – ABS\/316SS\u003cbr\u003eTemperature Probe – 316SS\u003cbr\u003eO-rings - EPDM\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensor Specifications:\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHI-7698194-0 pH sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Measurement type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003epH, mV (pH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Measurement range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 13.00 pH; ±600.0mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Temperature range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Colour Code\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Materials\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGlass tip, Low temperature glass, ceramic junction, PEI body, electrolyte gel and double reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Maintenance solution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-70300 storage solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Dimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e118 x 15mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHI-7698194-1 pH\/ORP sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Measurement type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003epH, mV (pH), ORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Measurement range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 13.00 pH; ±600.0mV; ±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Temperature range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Colour Code\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Materials\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGlass tip (pH); Pt (ORP), Low temperature glass, ceramic junction, PEI body, electrolyte gel and double reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Maintenance solution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-70300 storage solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Dimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e118 x 15mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHI-7698594-4 EC\/Turbidity sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Measurement type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eEC; FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Measurement range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 200.0 mS\/cm\u003cbr\u003e0.0 to 400 mS\/cm (absolute)\u003cbr\u003e0.0 to 1000 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Temperature range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Colour Code\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Materials\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: ABS\/EPOXY PMMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Maintenance solution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Dimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e111 x 17mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHI-7698594-3 EC sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Measurement type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Measurement range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 200.0 mS\/cm\u003cbr\u003e0.0 to 400 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Temperature range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Colour Code\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Materials\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: ABS\/EPOXY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Maintenance solution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Dimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e111 x 17mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHI-7698594-5 optical; luminescence quenching DO sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Measurement type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDO (% saturation and concentration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Measurement range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 500.0 %\u003cbr\u003e0.00 to 50.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Temperature range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Colour Code\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Materials\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePolypropylene tip; Body - ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Maintenance solution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Dimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e99 x 17mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrdering information\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAll models are supplied with: pH\/ORP sensor, EC\/Turbidity sensor, long protective probe shield, optical DO sensor, quick calibration solution, zero oxygen solution, 0 FNU calibration Solution (230ml, 20 FNU calibration solution (230ml), 200 FNU calibration solution (230ml), probe maintenance kit, USB type-C cable, calibration breaker, batteries x 4, quality certificate, and instruction manual in a rugged carrying case with custom insert.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSkus\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eHI-98594 is supplied with multiparameter probe with 4 metre cable\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHI-98594\/10 is supplied with multiparameter probe with 10 metre cable\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHI-98594\/20 is supplied with multiparameter probe with 20 metre cable\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHI-98594\/30 is supplied with multiparameter probe with 30 metre cable\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHI-98594\/40 is supplied with multiparameter probe with 40 metre cable\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHI-98594\/50 is supplied with multiparameter probe with 50 metre cable\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccessories to buy separately\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eHI-710034 Orange protective rubber boot\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHI-7004m pH 4.01 buffer solution, 230ml\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHI-7007m pH 7.01 buffer solution, 230ml\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHI-9829-16 0 FNU calibration solution, 230ml\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHI-9829-17 20 FNU calibration solution, 230ml\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHI-9829-18 200 FNU calibration solution, 230ml\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHI-7030m 12880µS\/cm calibration solution, 230ml\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHI-7031m 1413µS\/cm calibration solution, 230ml\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHI-7033m 84µS\/cm calibration solution, 230ml\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHI-7034m 80000µS\/cm calibration solution, 230ml\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHI-7035m 11180µS\/cm calibration solution, 230ml\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHI-7039m 5000µS\/cm calibration solution, 230ml\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":54495217385795,"sku":"HI-98594","price":4184.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1864\/8365\/files\/3228.webp?v=1779359937","url":"https:\/\/korallifarmi.fi\/products\/hi-98594-multiparameter-meter-with-bluetooth-connectivity","provider":"Korallifarmi","version":"1.0","type":"link"}