{"product_id":"hi-98192-professional-waterproof-ec-tds-resistivity-salinity-meter","title":"HI-98192 Professional Waterproof EC\/TDS\/Resistivity\/Salinity Meter","description":"\u003cp\u003eThe HI-98192 is a waterproof, portable conductivity meter that has an expanded conductivity range from 0.000µS\/cm to 400 mS\/cm, as well as TDS, resistivity and three salinity scales. This meter automatically recognises the probe type (two or four ring) and allows the user to adjust the nominal cell constant.\u003c\/p\u003e\n\u003cp\u003eHI-98192 is also ready to perform all three stages USP \u0026lt;645\u0026gt; method required for EC measurement of ultrapure water. Choose from seven memorised standards and obtain up to a five point conductivity calibration. For salinity (% range), HI-7037 standard allows users to make a one point calibration.\u003c\/p\u003e\n\u003cp\u003eEC and TDS measurements are fully customisable and include: cell constant selection between 0.010 and 10.000, selection of linear or natural water (non-linear) or no temperature compensation (for actual conductivity reading), configurable temperature compensation coefficient range from 0.00 to 10.00%\/°C, choice of reference temperatures of 15°C, 20°C and 25°C, and a selectable TDS factor between 0.40 and 1.00.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eQuick connect probe\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe HI-763133 four ring Stainless Steel conductivity probe features a quick connect DIN connector to make attaching and removing the probe simple and easy.\u003c\/p\u003e\n\u003ch3\u003eData Logging\u003c\/h3\u003e\n\u003cp\u003eThe HI-98192 allows storage of up to 400 log-on-demand samples or 1000 lot logging samples that can be later transferred to a PC with the supplied HI-920015 USB cable and HI-92000 software.\u003c\/p\u003e\n\u003ch3\u003eGLP\u003c\/h3\u003e\n\u003cp\u003eComprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including date, time and calibration values are stored for retrieval at a later time.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIP67 rated waterproof, rugged enclosure\u003c\/li\u003e\n\u003cli\u003eSalinity readings - Salinity can be displayed as % NaCl, seawater scale (ppt) or practical salinity scale (PSU)\u003c\/li\u003e\n\u003cli\u003eCalibration - perform up to a five point calibration for enhanced accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBacklit Graphic LCD Display\u003c\/h3\u003e\n\u003cp\u003eThe HI-98192 features a backlit graphic LCD with on-screen help. The graphic display allows for the use of virtual keys to provide for an intuitive user interface.\u003c\/p\u003e\n\u003ch3\u003eWaterproof Protection\u003c\/h3\u003e\n\u003cp\u003eThe meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes.\u003c\/p\u003e\n\u003ch3\u003eQuick connect probe\u003c\/h3\u003e\n\u003cp\u003eThe HI-763133 four-ring stainless steel conductivity probe features a quick connect DIN connector to make attaching and removing the probe simple and easy.\u003c\/p\u003e\n\u003ch3\u003ePC Connectivity\u003c\/h3\u003e\n\u003cp\u003eLogged data can be transferred to a Windows compatible PC with the included HI-920015 micro USB cable and HI-92000 software.\u003c\/p\u003e\n\u003ch3\u003eCalibration\u003c\/h3\u003e\n\u003cp\u003eChoose from seven memorized standards and obtain up to a five point conductivity calibration. For salinity (% range), HI-7037 standard allows users to perform a one point calibration.\u003c\/p\u003e\n\u003ch3\u003eUSP \u0026lt;645\u0026gt;\u003c\/h3\u003e\n\u003cp\u003eHI-98192 can be used to perform all three stages of USP method required for EC measurement of ultrapure water and generates a report when the any of the three stages are met.\u003c\/p\u003e\n\u003cp\u003eThree stages of conformity:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePerforms all 3 stages of USP \u0026lt;645\u0026gt; water quality testing requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOn-screen guide:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUsers are provided with on-screen instructions for each USP stage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProgress bar:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisplays reading stability progress towards meeting stage 2 requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMeasurement\u003c\/h3\u003e\n\u003cp\u003eEC and TDS measurements are fully customizable and include: cell constant selection between 0.010 and 10.000, selection of linear or natural water (nonlinear) or no temperature compensation (for actual conductivity reading), configurable temperature compensation coefficient range from 0.00 to 10.00%\/°C, choice of reference temperatures of 15°C, 20°C and 25°C, and a selectable TDS factor between 0.40 and 1.00. Ten sets of customized measurement parameters can be stored as a user profile and later recalled.\u003c\/p\u003e\n\u003ch3\u003eAutoHold\u003c\/h3\u003e\n\u003cp\u003ePressing AutoHold during measurement will automatically hold the first stable reading on the display.\u003c\/p\u003e\n\u003ch3\u003eDedicated Help Key\u003c\/h3\u003e\n\u003cp\u003eContextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting\/option being viewed.\u003c\/p\u003e\n\u003ch3\u003eSupplied with\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHI-763133 platinum four ring conductivity\/TDS probe\u003c\/li\u003e\n\u003cli\u003eHI-7031M\u003c\/li\u003e\n\u003cli\u003eHI-7035M\u003c\/li\u003e\n\u003cli\u003eRugged carrying case\u003c\/li\u003e\n\u003cli\u003e100mL plastic beaker (2)\u003c\/li\u003e\n\u003cli\u003eHI-92000 PC software\u003c\/li\u003e\n\u003cli\u003eHI-920015 micro USB cable\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eInstruction manual\u003c\/li\u003e\n\u003cli\u003eQuality certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC - Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 400 mS\/cm (shows values up to 1000 mS\/cm), actual conductivity 1000 mS\/cm**; 0.001 to 9.999 µS\/cm*; 10.00 to 99.99 µS\/cm; 100.0 to 999.9 µS\/cm; 1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm (autoranging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 µS\/cm*; 0.01 µS\/cm; 0.1 µS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.01µS\/cm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic up to five points with seven memorised standards (0.00 µS\/cm, 84.0 µS\/cm, 1.413 mS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS - Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 99.99 mg\/L (ppm); 100.0 to 999.9 mg\/L (ppm); 1.000 to 9.999 g\/L (ppt); 10.00 to 99.99 g\/L (ppt); 100.0 to 400.0 g\/L (ppt) (autoranging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 mg\/L (ppm); 0.001 g\/L (ppt); 0.01 g\/L (ppt); 0.1 g\/L (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.05 mg\/L (ppm) or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity - Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω. cm; 100 to 999 Ω. cm; 1.00 to 9.99 KΩ. cm; 10.0 to 99.9 KΩ. cm; 100 to 999 KΩ. cm; 1.00 to 9.99 MΩ. cm; 10.0 to 100.0 MΩ. cm* (autoranging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω. Cm; 1 Ω. Cm; 0.01 KΩ. cm; 0.1 KΩ. cm; 1 KΩ. cm; 0.01 MΩ. cm; 0.1 MΩ. cm*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±10 Ω or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity - Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e% NaCl: 0.0 to 400.0 %; practical salinity: 0.00 to 42.00 (PSU); seawater scale: 0.00 to 80.00 (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 %; 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003emax. one point only in % range (with HI-7037 standard); use conductivity calibration for all other ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature - Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2°C (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eone or two points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Specifications:\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Constant Setup\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.010 to 10.000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNoTC, linear (-20.0 to 120.0°C), non linear (0 to 36°C) ISO\/DIS 7888 std\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e15°C, 20°C and 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS factor\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.40 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-763133 stainless steel, four-ring conductivity\/TDS probe with internal temperature sensor and 1.5 m (4.9’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003elog-on demand: 400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemorised Profiles\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautorange, autoend, lock and fixed range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Connectivity\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eopto-isolated sealed USB (with HI-92000 software and micro USB cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4)\/approximately 100 hours of continuous use (without backlight), 25 hours with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003euser selectable: 5, 10, 30, 60 min, disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C; RH 100% IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\/Weight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e185 x 95 x 35.2 mm\/400g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":54497610989891,"sku":"HI-98192","price":1139.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1864\/8365\/files\/1697.webp?v=1779442003","url":"https:\/\/korallifarmi.fi\/sv\/products\/hi-98192-professional-waterproof-ec-tds-resistivity-salinity-meter","provider":"Korallifarmi","version":"1.0","type":"link"}