{"product_id":"pca340-free-total-chlorine-ph-c-controller-analyser","title":"PCA340 Free \u0026 Total chlorine, pH \u0026 °C controller\/analyser","description":"\u003cp\u003eThe PCA family are process analysers for the continuous measurement of chlorine and temperature. Also, pH (PCA320, PCA330, PCA340) and ORP where specified. The analysers feature built in data logging, RS 485 digital output, dosing relays, and alarm relays packaged in a wall mount Nema 4 x enclosure. The PCA340 also features two analog outputs.\u003c\/p\u003e\n\u003cp\u003eFrom drinking and wastewater treatment to pool and spa sanitation, monitoring chlorine levels has an important bearing on public health. It can also help with the running efficiency for heating system and industrial applications.\u003c\/p\u003e\n\u003ch3\u003eChlorine, pH, ORP and Temperature analysers\u003c\/h3\u003e\n\u003cp\u003eThe PCA300 family uses DPD Colorimetric method in which N, N-Diethyl-p-phenylenediamine indicator and a buffer are mixed together with the sample. The resulting chemical reaction causes a magenta colour to form in the presence of chlorine. The colour intensity is proportional to the concentration. The colour intensity is measured photometrically (light source at a specific wavelength and a photodetector) and converted to chlorine concentration, in mg\/L, which is displayed on the front panel. The sampling interval for chlorine measurement is adjustable from 3 to 90 minutes.\u003c\/p\u003e\n\u003cp\u003eThe analysers have a dosing relay for the addition of chlorine by a dosing pump or chlorine generator when a reading is below the programmable set point. The technology used by this family for chlorine measurement is the same as that found in portable and benchtop colorimeters providing for consistent results when performing process verification with one of those types of meters.\u003c\/p\u003e\n\u003cp\u003eThe PCA320, 330 and 340 also utilise the HI-1005 amplified pH electrode with a built in pt100 temperature sensor and matching pin to measure both pH and temperature. The built in amplifier and matching pin provide for exceptional performance against any electrical noise generated by pumps and motors. These analysers have a programmable dosing relay for the adjustment of pH. The dosing relay can be activated by either on\/off or proportional control.\u003c\/p\u003e\n\u003cp\u003eThe PCA340 features two selectable 0.20 or 4-20 mA signal output that are scalable for the transmission of readings to external recording devices. The analog outputs can also be set for dosing and used with dosing pumps that accept a 4-20mA analog input. The analog outputs can be used for any of the three measured parameters.\u003c\/p\u003e\n\u003cp\u003eThrough the system setup menu, users have the ability to enable or disable the low and high level of alarms for all parameters. The PCA family also offers overdosing protection that generates an alarm if something within the system is not working properly. The system will stop processes until the user corrects the error.\u003c\/p\u003e\n\u003ch3\u003eBacklit LCD Display\u003c\/h3\u003e\n\u003cp\u003eThe PCA family has a backlit display that is easy to read from a distance and allows for up to three parameters to be displayed at a time.\u003c\/p\u003e\n\u003ch3\u003eNema 4x protection\u003c\/h3\u003e\n\u003cp\u003eThe analysers are enclosed in waterproof casing for superior protection against the elements. The front door of the case has a window for the measurement display while also shielding the DPD reagents from UV light to prevent premature degradation.\u003c\/p\u003e\n\u003ch3\u003eDPD Chlorine Measurement Method\u003c\/h3\u003e\n\u003cp\u003eThe DPD colorimetric method is one of the most common and reliable methods to measure chlorine. The PCA family can use either free or total chlorine reagents and allow for 16,000 measurements to be performed.\u003c\/p\u003e\n\u003ch3\u003eReagent Reminder\u003c\/h3\u003e\n\u003cp\u003eThe PCA family has a reagent reminder feature to alert the user when the reagents are running low. When the reagents are changed, the counter is reset and the meter automatically tracks the number of readings performed.\u003c\/p\u003e\n\u003ch3\u003eColorimeter Diagnostics\u003c\/h3\u003e\n\u003cp\u003eAdvanced diagnostics allow for easy troubleshooting of the colorimeter. In the setup menu it is possible to select an option that allows the user to determine the difference between a dark read (LED off) and blank read (LED on). These analysers also automatically perform this check in order to determine when to alert the user that the sample cell needs to be cleaned.\u003c\/p\u003e\n\u003ch3\u003eAmplified pH\/Temperature, probe (PCA320, PCA330 and PCA340)\u003c\/h3\u003e\n\u003cp\u003eAn integrated pt100 temperature sensor allows for automatic temperature compensation of pH measurements and allows for monitoring temperature as well. The built in amplifier and matching pin provides for exceptional performance where other probes fail when placed in line with pumps and motors.\u003c\/p\u003e\n\u003ch3\u003eData logging\u003c\/h3\u003e\n\u003cp\u003eThe analysers can store up to 3500 readings (at least 7 days worth of records when set to a 3 minute sampling interval) that can be reviewed or downloaded to a Windows compatible PC using the HI-92500 software and the RS485 serial port. Logged records contain the date, time and reading of all parameters measured along with any alarm status.\u003c\/p\u003e\n\u003ch3\u003eGLP Data\u003c\/h3\u003e\n\u003cp\u003eThe GLP data allows for the user to review the data and time for the last chlorine and pH calibration.\u003c\/p\u003e\n\u003ch3\u003eDigital RS485 output\u003c\/h3\u003e\n\u003cp\u003eThe analysers have a RS485 digital output that allows for connection to a Windows compatible PC running the HI-925000 software. The software allows for remote monitoring, review of logged data, events and errors, and executing setup options.\u003c\/p\u003e\n\u003ch3\u003eWarning messages\u003c\/h3\u003e\n\u003cp\u003eError messages are displayed when the reagents are expired or low and if the colorimeter cell needs to be cleaned.\u003c\/p\u003e\n\u003ch3\u003eTwo analog outputs (PCA340)\u003c\/h3\u003e\n\u003cp\u003eThe PCA340 features two selectable 0-20 or 4-20 mA signal output that are scalable for the transmission of readings to external recording devices. The analog outputs can also be set for dosing and used with dosing pumps that accept a 4-20 mA analog input. The analog outputs can be used for any of the three measured parameters.\u003c\/p\u003e\n\u003ch3\u003eTwo dosing relays\u003c\/h3\u003e\n\u003cp\u003eThe dosing relays of the analysers can be connected to a pH and\/or chlorine dosing pumps. The chlorine relays are proportionally controlled, while the pH relay can be set for on\/off or proportional control. The proportional control offers very fine control of doing to prevent any overshoot and wastage of chemicals.\u003c\/p\u003e\n\u003ch3\u003eAlarm relay\u003c\/h3\u003e\n\u003cp\u003eOne SPDT alarm relay is provided that can be activated by adjustable upper and lower chlorine, pH and temperature limits.\u003c\/p\u003e\n\u003ch3\u003eError relay\u003c\/h3\u003e\n\u003cp\u003eOne SPDT error relay is provided and is activated when an error is present, including a problem with the colorimeter - such as when the reagent counter has reached zero, or when a reading is outside the range for a measured parameter.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBacklit LCD Display\u003c\/li\u003e\n\u003cli\u003eNema 4x protection\u003c\/li\u003e\n\u003cli\u003eDPD Chlorine measurement method\u003c\/li\u003e\n\u003cli\u003eColorimeter diagnostics\u003c\/li\u003e\n\u003cli\u003eReagent reminder\u003c\/li\u003e\n\u003cli\u003eAmplified pH\/temperature probe\u003c\/li\u003e\n\u003cli\u003eData logging of up to 3500 measurements\u003c\/li\u003e\n\u003cli\u003eGLP data for review of calibration information\u003c\/li\u003e\n\u003cli\u003eDigital RS485 output\u003c\/li\u003e\n\u003cli\u003eTwo analog outputs for recording or dosing devices (PCA340)\u003c\/li\u003e\n\u003cli\u003eTwo dosing relays\u003c\/li\u003e\n\u003cli\u003eSPDT alarm relay\u003c\/li\u003e\n\u003cli\u003eSPDT system error relay\u003c\/li\u003e\n\u003cli\u003eWarning messages\u003c\/li\u003e\n\u003cli\u003eEach PCA 300 series model is supplied with reagent bottles (2), reagent caps (2), 1 DPD compound powder, tubing and instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAbout chlorine\u003c\/h3\u003e\n\u003cp\u003eChlorine is a strong oxidising agent that destroys mostly organic pollutants and bacteria and can combine with nitrogen containing compounds, forming chloramines. When dosing chlorine for disinfection, only a portion of the dosed chlorine remains active to actually continue the disinfection process.\u003c\/p\u003e\n\u003cp\u003eWhen free chlorine combines with a nitrogen containing compound, it becomes a less efficient disinfectant called chloramines. The addition of these two parts gives total chlorine. The target is to keep free and total chlorine equal, and to maintain the combined chlorine concentration (chloramines) near zero. The presence of chloramines is not desired because of the distinctive ‘swimming pool’ smell caused by combined chlorines like di-chloramines. Beside this unpleasant odour, chloramines can irritate the eyes and the mucous membranes.\u003c\/p\u003e\n\u003ch3\u003e. . . . More about chlorine\u003c\/h3\u003e\n\u003cp\u003eCommercial chlorine for disinfection may be available as a gas (Cl\u003csub\u003e2\u003c\/sub\u003e), a liquid like sodium hypochlorite or bleach (NaOCl), or in a solid state like calcium hypochlorite, chloro-hydantoins or chloro-cyanuric acid compounds. These compounds, once dissolved in water, do establish equilibrium between the hypochlorous acid (HOCl) and the hypochlorite ions (OCl\u003csup\u003e-\u003c\/sup\u003e). Although both forms are considered free chlorine, it is the hypochlorous acid that provides the strongest disinfecting and oxidising characteristics of chlorine solutions.\u003c\/p\u003e\n\u003cp\u003eThe amount of hypochlorous acid in chlorinated water depends on the pH value of the solution. Changes in pH value will affect the HOCl equilibrium in relation to the hydrogen and hypochlorite ion. HOCl decreases and OCl\u003csup\u003e-\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eincreases as pH increases. At a low pH, almost all the free chlorine is in the molecular form HOCl and at a pH of around 7.5, the ratio between HOCl and OCl\u003csup\u003e-\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eis 50:50.\u003c\/p\u003e\n\u003cp\u003eSince the ionic form OCl\u003csup\u003e-\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eis a slow acting sanitiser while the molecular HOCl is a fast acting, it is important to regularly measure the pH. As a general rule, a pH of about 7.2 is recommended to maintain fast acting disinfection conditions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFREE AND TOTAL CHLORINE\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePCA310, PCA320, PCA330 \u0026amp; PCA340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e?Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e?Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e?Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±8% or ±0.05 mg\/L whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePCA320, PCA330 \u0026amp; PCA340 only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e?Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e?Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e?Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.05pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePCA330 only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e?Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e?Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e?Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEMPERATURE\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePCA320, PCA330 \u0026amp; PCA340 only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e?Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e5°C to 75.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e?Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e?Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eANALOGUE OUTPUT – PCA340 only\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e(2) 4-20mA, 0-20mA for recorder or dosing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003eADDITIONAL SPECIFICATIONS:\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eone-point process calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Sampling Rate\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable from 3 to 90 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dosage\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eproportional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Delta\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable from 0.1 to 5 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic one or two points; one point process calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Sampling Rate\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable from 3 to 120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Dosing\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eON\/OFF or proportional, relay or 4-20mA output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Delta\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable from 0.1 to 2pH (hysteresis adjustable from 0.05 to 2pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder output – PCA310, PCA320 \u0026amp; PCA330\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20mA, 0-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Connectivity\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRS485 port, galvanically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1200, 2400, 4800, 9600 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData logging\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 3500 data points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm relay\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSPDT contact with 5A, 230V resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing relay\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSPDT contact with 5A, 230V resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem error\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSPDT contact with 5A, 230V resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet pressure\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.07 to 4 bar with no external pressure regulator (for pressure exceeding four bar an external pressure regulator is required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample flow\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e100 to 300 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample temperature\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample inlet\/outlet connection\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e12mm male NPT fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain connection\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e10mm barb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e230 VAC ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA-4X Standard, moulded fiberglass polyester with transparent Lexan window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\/weight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e318 x 267 x 159mm\/5kg without reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCA310\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFree and total chlorine analyser\/controller (230V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCA320\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFree and total chlorine analyser\/control, pH control, temperature (230V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCA330\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFree and total chlorine analyser\/control, pH control, ORP monitoring, temperature (230V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCA340\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFree and total chlorine analyser\/control, pH control, temperature with dual analogue outputs (230V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePARTS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70473\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePCA tubing kit, pressure regulator to drain (2). Each kit includes: transparent Tygon tubes 86L x 3.2ID mm (Length x Internal Diameter) and 105 x 9.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70474\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePCA peristaltic pump tubing kit (6). Each kit includes: non- transparent C-flex tubes 55L x 0.8ID mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70475\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePCA peristaltic pump tubing kit (2). Each kit includes: non- transparent C-flex tubes 55L x 0.8ID mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70476\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePCA reagent bottle tubing kit (6). Each kit includes: non- transparent C-flex tubes 155L x 0.8ID mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70478\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePCA tubing kit, bottle to pump (6 ). Each kit includes: non- transparent C-flex tube 150L x 0.8ID mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70479\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePCA tubing kit, pump to Y strainer (6 pcs). Each kit includes: non-transparent C-flex tube 150L x 0.8ID mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70482\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePCA filters. The kit includes 0.5 µm and 50 µm filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70496\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eReplacement filter, 0.5 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70497\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eReplacement filter, 50 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70484\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePCA complete tubing kit. The kit includes: non-transparent C-flex tubes 150L x 0.8ID (4 pcs), non-transparent C-flex tubes 55L x 0.8ID (2 pcs), non-transparent C-flex tubes 50L x 0.8ID and Y strainer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70485\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePCA stirrer motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70486\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePCA Stirring bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-704871\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMeasuring cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70488\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrovalve 24VAC\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70489\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrovalve 24VAC\/50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70492\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode holder (PCA330)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70493\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosing cap for electrode holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eELECTRODES\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-1005\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAmplified pH electrode with matching pin and Pt100 (PCA320\/330 only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-2008\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAmplified ORP electrode with Matching Pin (PCA 330 only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eREAGENT SETS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70481\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal Chlorine Reagent set for PCA buffer citrate, 500ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70430\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFree chlorine reagents set for PCA (the most stable), recommended for long term measurements, 500 mL (2) + 6 g powder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70480\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFree chlorine reagents set for PCA, recommended for short term measurements, 500 mL (2) + 5 sachets (DPD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70490\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFree chlorine reagents set for PCA, 500 mL (2) + 5 sachets (DPD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70452\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDPD reagent, 5 sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOLUTIONS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70460\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal chlorine indicator solution for PCA, 500ml – (After addition of 5 powder sachets (HI-70452-0))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70461\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal chlorine buffer solution for PCA, 500ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70450\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFree chlorine indicator solution for PCA, 500ml – (After addition of 5 powder sachets (HI-70452-0))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70451\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFree chlorine buffer solution for PCA, 500ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-7004L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003epH 4.01 buffer solution, 500ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-7006L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003epH 6.86 buffer solution, 500ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-7007L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003epH 7.01 buffer solution, 500ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-7009L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003epH 9.18 buffer solution, 500ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-7010L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003epH 10.01 buffer solution, 500ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-7020L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e200-275mV buffer solution, 500ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-7091L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePretreatment reducing solution, 500ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-7092L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePretreatment oxidizing solution, 500ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70300L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStorage solution, 500ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-7082\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5M KCL electrolyte, 30ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-7061L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode cleaning solution, 500ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOFTWARE\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-92500\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows® compatible software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":54527906873667,"sku":"PCA340-2","price":2659.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1864\/8365\/files\/2014.webp?v=1780654181","url":"https:\/\/korallifarmi.fi\/sv\/products\/pca340-free-total-chlorine-ph-c-controller-analyser","provider":"Korallifarmi","version":"1.0","type":"link"}