| pH/mV Range |
|
0.00 to 14.00 pH/± 600.0 mV |
| Resolution |
|
0.01 pH/ 0.1 mV |
| Accuracy |
|
±0.02 pH/ ±0.5 mV |
| Calibration |
|
automatic one, two or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer |
| ORP Range |
|
±2000.0 mV |
| ORP Resolution |
|
0.1 mV |
| ORP Accuracy |
|
±1.0 mV |
| ORP Calibration |
|
automatic at one custom point (relative mV) |
| EC Range |
|
0 to 200 mS/cm (absolute EC up to 400 mS/cm) |
| EC Resolution |
|
Manual: 1μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; automatic: 1μS/cm from 0 to 9999 μS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm |
| EC Accuracy |
|
±1% of reading or ± 1μS/cm whichever is greater |
| EC Calibration |
|
automatic single point, with six standard solutions (84μS/cm, 1413μS/cm, 5.00mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
| TDS Range |
|
0 to 400.0 ppt (g/L) (the maximum value depends on the TDS factor) |
| TDS Resolution |
|
manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); automatic: 1ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 PPT(g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 pp (g/L) |
| TDS Accuracy |
|
±1% of reading or ±1 ppm (mg/L) whichever is greater |
| TDS Calibration |
|
based on conductivity or salinity calibration |
| Resistivity Range |
|
0 to 999999 Ω.cm; 0 to 1000.0 kΩ.cm; 0 to 1.0000 MΩ.cm |
| Resistivity Resolution |
|
dependent on resistivity reading |
| Resistivity Calibration |
|
based on conductivity or salinity calibration |
| Salinity Range |
|
0.00 to 70.00 PSU |
| Salinity Resolution |
|
0.01 PSU |
| Salinity Accuracy |
|
±2% of reading or ±0.01 PSU whichever is greater |
| Salinity Calibration |
|
based on conductivity calibration |
| Seawater σ Range |
|
0.0 to 50.0 σt, σ0, σ15
|
| Seawater σ Resolution |
|
0.1 σ t, σ0, σ 15
|
| Seawater σ Accuracy |
|
±1 σ t, σ0, σ 15
|
| Seawater σ Calibration |
|
based on conductivity or salinity calibration |
| Temperature Range |
|
-5.00 to 55.00°C |
| Temperature Resolution |
|
0.01°C |
| Temperature Accuracy |
|
±0.15°C |
| Temperature Calibration |
|
Automatic at one custom point |
| Additional Specifications |
|
|
| Maximum probe immersion |
|
Depth - 20 metres |
| Temperature compensation |
|
automatic from -5 to 55°C |
| Logging Memory |
|
45,000 records (continuous logging or log-on demand of all parameters |
| Logging Interval |
|
one second to three hours |
| PC Connectivity |
|
via USB (with Hanna PC software) |
| Environment |
|
0 to 50°C; RH 100% IP67 |
| Battery Type/Life |
|
1.5V AA batteries (4)/approximately 360 hours of continuous use without backlight (50 hours with backlight) |
| Dimensions/Weight |
|
185 x 93 x 35.2 mm/400g |
| Ordering information: |
|
HI-98195 is supplied with HI-7698195/4 multiparameter probe, HI-7698194-1 pH/ORP sensor, HI-7698194-3 EC sensor, HI-9828-20 quick calibration solution, HI-76981952 probe maintenance kit, HI-76981943 calibration beaker, HI-9298194 Hanna PC software, HI-920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom insert. |