HI-98195 provides multi-parameter measurement in a compact and rugged IP67 waterproof enclosure. Ideal for demanding applications, this meter features our rugged, quick-connect multi-function probe with field-replaceable sensors.
A backlit, graphic LCD provides easy-to-read resolution even in low-lit areas. A combination of dedicated and soft keys allows for easy, intuitive operation in a choice of languages.
HI-98195 allows users to store up to 45,000 continuous or log-on-demand samples with logging intervals from one second to three hours. Logged data can later be transferred to a PC with the HI-920015 micro USB cable and Hanna software.
Comprehensive GLP data includes information from the last five calibrations. The contextual Help Menu can be accessed to obtain on-screen information and assistance regarding each feature at the touch of a button.
IP68 - The electrode is dust-tight and protected against the effects of continuous immersion in water beyond 1m.
PC Interface - Download test results to a computer programmed with HANNA’s Windows®-compatible software (HI-92000), directly from the equipment via a USB port or an RS232 cable outlet.
| pH/mV Range | 0.00 to 14.00 pH / ± 600.0 mV | |
| Resolution | 0.01 pH / 0.1 mV | |
| Accuracy | ±0.02 pH / ±0.5 mV | |
| Calibration | Automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer | |
| ORP Range | ±2000.0 mV | |
| ORP Resolution | 0.1 mV | |
| ORP Accuracy | ±1.0 mV | |
| ORP Calibration | Automatic at one custom point (relative mV) | |
| EC Range | 0 to 200 mS/cm (absolute EC up to 400 mS/cm) | |
| EC Resolution | Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; Automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm | |
| EC Accuracy | ±1% of reading or ± 1 µS/cm, whichever is greater | |
| EC Calibration | Automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point | |
| TDS Range | 0 to 400.0 ppt (g/L) (the maximum value depends on the TDS factor) | |
| TDS Resolution | Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); Automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); Automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L) | |
| TDS Accuracy | ±1% of reading or ±1 ppm (mg/L), whichever is greater | |
| TDS Calibration | Based on conductivity or salinity calibration | |
| Resistivity Range | 0 to 999999 Ω·cm; 0 to 1000.0 kΩ·cm; 0 to 1.0000 MΩ·cm | |
| Resistivity Resolution | Dependent on resistivity reading | |
| Resistivity Calibration | Based on conductivity or salinity calibration | |
| Salinity Range | 0.00 to 70.00 PSU | |
| Salinity Resolution | 0.01 PSU | |
| Salinity Accuracy | ±2% of reading or ±0.01 PSU, whichever is greater | |
| Salinity Calibration | Based on conductivity calibration | |
| Seawater σ Range | 0.0 to 50.0 σt, σ0, σ15 | |
| Seawater σ Resolution | 0.1 σt, σ0, σ15 | |
| Seawater σ Accuracy | ±1 σt, σ0, σ15 | |
| Seawater σ Calibration | Based on conductivity or salinity calibration | |
| Temperature Range | -5.00 to 55.00°C | |
| Temperature Resolution | 0.01°C | |
| Temperature Accuracy | ±0.15°C | |
| Temperature Calibration | Automatic at one custom point | |
| Additional Specifications | ||
| Maximum probe immersion | Depth - 20 meters | |
| Temperature compensation | Automatic from -5 to 55°C | |
| Logging Memory | 45,000 records (continuous logging or log-on-demand of all parameters) | |
| Logging Interval | One second to three hours | |
| PC Connectivity | Via USB (with Hanna PC software) | |
| Environment | 0 to 50°C; RH 100% IP67 | |
| Battery Type/Life | 1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight) | |
| Dimensions/Weight | 185 x 93 x 35.2 mm / 400g | |
| Ordering information: | HI-98195 is supplied with HI-7698195/4 multiparameter probe, HI-7698194-1 pH/ORP sensor, HI-7698194-3 EC sensor, HI-9828-20 quick calibration solution, HI-76981952 probe maintenance kit, HI-76981943 calibration beaker, HI-9298194 Hanna PC software, HI-920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom insert. |
| Vendor: | Hanna Instruments |
|---|---|
| SKU: | HI-98195 |
| Weight: | 1.5 kg |